HANNA HI839800 Benchtop COD Test Tube Heater

Brands:Hanna

Dijual & dikirim oleh: Darma Sakti Adiperkasa, CV
  • Temperature Of Reaction selectable, 105° C or 150° C
  • Temperature Stability ± 0.5° C
  • Capacity 25 vials ( dia 16 x 100 mm, 0.6 x 3.9 ” ) ,
  • 1 receptacle for a reference thermometer with stainless steel probe
  • Accuracy ± 2° C ( @ 25° C/ 77° F)
  • Warm Up Time approx. 30 minutes, depending on selected temperature
  • Operating Mode timed ( 0 to 120 minutes) or infinity mode
  • Timer Range 0 to 120 minutes with acoustic alarm and automatic shut-off
  • Block aluminum
  • Environment 5 to 50° C ( 41 to 122° F)
  • Power Supply 100 Vac, 50/ 60 Hz; 230 Vac; 50 Hz; 250W; 2A fuse ( See Chart)
  • Dimensions 190 x 300 x 95 mm ( 7.5 x 11.8 x 3.7 ” )
  • Weight 4.8 kg ( 10.6 lb.)

Report Abuse

HANNA HI839800 Benchtop COD Test Tube Heater

Description :

HI 839800 thermo-reactor is constructed of durable materials with a vial capacity to perform up to 25 digestions simultaneously. The reactor is equipped with 6 predifined and 2 user defined temperature profiles. Dedicated temperature profiles for COD and total phosphorous reactions at preset to 150° C. The total nitrogen analysis temperature is pre-set to 105° C.
In addition, HI 839800 features LED indicators for visual indication of power on and heating in progress.

heater block temperature can be verified by placing a thermometer in the temperature well provided in the block. In the adjustable temperature mode ( 50 to 150° C) , the instrument can be used for digestion of other samples that require different digestion temperatures. A 3-hour timer is incorporated for applications where timed digestion is desired. When this feature is used, the beeper will sound and the unit will shut off at the end of the selected time period. The timer can also be used without the shut-off feature when operating in the infinity mode.
The reactor is provided with a thermal fuse that prevents overheating, by disabling the heater.

Specifications :

Temperature Of Reaction selectable, 105° C or 150° C
Temperature Stability ± 0.5° C
Capacity 25 vials ( dia 16 x 100 mm, 0.6 x 3.9 ” ) ,
1 receptacle for a reference thermometer with stainless steel probe
Accuracy ± 2° C ( @ 25° C/ 77° F)
Warm Up Time approx. 30 minutes, depending on selected temperature
Operating Mode timed ( 0 to 120 minutes) or infinity mode
Timer Range 0 to 120 minutes with acoustic alarm and automatic shut-off
Block aluminum
Environment 5 to 50° C ( 41 to 122° F)
Power Supply 100 Vac, 50/ 60 Hz; 230 Vac; 50 Hz; 250W; 2A fuse ( See Chart)
Dimensions 190 x 300 x 95 mm ( 7.5 x 11.8 x 3.7 ” )
Weight 4.8 kg ( 10.6 lb.)

HANNA HI839800 Benchtop COD Test Tube Heater Dengan Harga murah dan cari produk terbaik lainnya dari kategori  dari pH Meter  Merek Hanna Gratis biaya pengiriman untuk wilayah Jakarta dan dapat dikirim ke seluruh Indonesia. Dapatkan hanya di toko online Kucari.com, belanja online alat ukur dan alat survey mudah dan aman.

Kucari.com menyediakan berbagai alat ukur dan instruments dari supplier dan distributor resmi yang tersebar dibeberapa kota di Indonesia seperti Jakarta, Bandung, Bekasi, Depok, Cikarang, Tangerang, Lampung, Pontianak, Jogja, Semarang, Solo, Batam, Padang, Pekanbaru, Malang, Surabaya, Medan, Makassar, Balikpapan, Samarinda, Pelembang, Riau, Aceh, Manado, dan Bali.

Daftarkan perusahaan Anda!

Anda adalah Agen, Vendor, Supplier & Distributor peralatan ukur dan perkakas untuk wilayah Indonesia? Daftarkan perusahaan Anda disini

Kucari.com merupakan situs penyedia direktori peralatan dan perkakas bisnis sebagai media promosi online berbasis web yang dapat menghubungkan supplier, distributor, agen, vendor dan pembeli antar bisnis (B2B – Business to Business) dan kalangan B2C (Business-to-Customer) dalam 24 Jam nonstop menjangkau seluruh wilayah Indonesia

Category: Tag:

Product Enquiry

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “HANNA HI839800 Benchtop COD Test Tube Heater”

There are no reviews yet.