  • Range : 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU
  • Resolution : 0.01; 0.1; 1 NTU
  • Range Selection : automatic
  • Accuracy : ±2% of reading plus 0.02 NTU
  • Repeatability : ±1% of reading or 0.02 NTU, whichever is greater
  • Stray Light : < 0.02 NTU
  • Light Detector : silicon photocell
  • Method : ratio nephelometric method (90° & 180°)

HANNA HI93414 Turbidity and Chlorine Meter

Description :

HI93414 is a high accuracy Turbidity and Chlorine Portable Meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI93414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.The chlorine measurements are are adapted EPA Method 330.5 and Standard Method 4500-Cl G.

Features :

Three Measurement Modes – The HI93414 features three options for measurement including ratio mode for turbidity, free chlorine, and total chlorine. Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range, while free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range
Multiple reading modes – Normal measurement, continuous measurement, or signal averaging measurement are reading modes available
EPA Compliant –  The HI93414 meets and exceeds the requirements of EPA and Standard Methods both for turbidity and colorimetric chlorine measurements. When the meter is in EPA mode all turbidity readings are rounded accordingly to meet reporting requirements
Calibration – A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.1, 15, 100, and 750 NTU) standards. Calibration points can be modified if user-prepared standards are used. For free and total chlorine, the 1.00 mg/L (ppm) CAL Check™ standard can be used for calibration and performance verification
AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.
CAL Check™  – With the powerful CAL Check™ function, reliable performance of the chlorine colorimeter can be validated at any moment by using the exclusive HANNA ready-made, NIST traceable standards.  All standards are supplied with a Certificate of Analysis (COA) for traceability
Fast Tracker™  – For advanced ˜field applications, the HI93414 is equipped with Fast Tracker™ – Tag Identi˜fication System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a speci˜fic measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identi˜cation code encased in stainless steel
GLP Data – The HI93414 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time
Data Logging – Up to 200 measurements can be stored in the internal memory and recalled at any time.
Data Transfer – For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB ports and the HI92000 software
Backlit Display – A backlit LCD display provides an easy to understand, user-friendly interface. Displayed codes guide the user step-by-step through routine operation and calibration
The HI98703 is a high accuracy (+0.02 NTU) Turbidity Portable Meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI98703 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.

Specifications :

Range : 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU
Resolution : 0.01; 0.1; 1 NTU
Range Selection : automatic
Accuracy : ±2% of reading plus 0.02 NTU
Repeatability : ±1% of reading or 0.02 NTU, whichever is greater
Stray Light : < 0.02 NTU
Light Detector : silicon photocell
Method : ratio nephelometric method (90° & 180°)
Measuring Mode : normal, average, continuous
Turbidity Standards : < 0.1, 15, 100, and 750 NTU
Calibration : two, three, or four-point calibration
Free and Total Chlorine Range : 0.00 to 5.00 mg/L (ppm)
Free and Total Chlorine Resolution : 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L (ppm); 0.10 above 3.50 mg/L (ppm)
Log Memory : 200 records
Connectivity : USB or RS232
Environment : 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply : 1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions : 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)
Weight : 512 g (18 oz.)

Includes :

Sample cuvettes and caps (5)
HI98703-11 calibration cuvettes for turbidity
HI93414-11 calibration cuvettes for chlorine
Silicone oil
Cuvette wiping cloth
Scissors
Batteries
AC adapter
Instruction manual
Rugged carrying case.

HANNA HI93414 Turbidity and Chlorine Meter Dengan Harga murah dan cari produk terbaik lainnya dari kategori  dari Turbidity Meter  Merek Hanna Gratis biaya pengiriman untuk wilayah Jakarta dan dapat dikirim ke seluruh Indonesia. Dapatkan hanya di toko online Kucari.com, belanja online alat ukur dan alat survey mudah dan aman.

Kucari.com menyediakan berbagai alat ukur dan instruments dari supplier dan distributor resmi yang tersebar dibeberapa kota di Indonesia seperti Jakarta, Bandung, Bekasi, Depok, Cikarang, Tangerang, Lampung, Pontianak, Jogja, Semarang, Solo, Batam, Padang, Pekanbaru, Malang, Surabaya, Medan, Makassar, Balikpapan, Samarinda, Pelembang, Riau, Aceh, Manado, dan Bali.

Daftarkan perusahaan Anda!

Anda adalah Agen, Vendor, Supplier & Distributor peralatan ukur dan perkakas untuk wilayah Indonesia? Daftarkan perusahaan Anda disini

Kucari.com merupakan situs penyedia direktori peralatan dan perkakas bisnis sebagai media promosi online berbasis web yang dapat menghubungkan supplier, distributor, agen, vendor dan pembeli antar bisnis (B2B – Business to Business) dan kalangan B2C (Business-to-Customer) dalam 24 Jam nonstop menjangkau seluruh wilayah Indonesia

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “HANNA HI93414 Turbidity and Chlorine Meter”

There are no reviews yet.