HANNA HI93414 Turbidity and Chlorine Meter

Add your review

  • Range : 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU
  • Resolution : 0.01; 0.1; 1 NTU
  • Range Selection : automatic
  • Accuracy : ±2% of reading plus 0.02 NTU
  • Repeatability : ±1% of reading or 0.02 NTU, whichever is greater
×
Metode Pembayaran
Transfer Bank (BCA, Mandiri, BRI, BNI)
BCA KlikPay
Kartu Kredit / Debit Online
Cash on Delivery (COD)*
Pembayaran Tempo (TOP)
Down Payment (DP)*
Lihat Metode Pembayaran Selengkapnya
Metode Pembayaran
×
Wilayah PengirimanEstimasi Pengiriman
Jabodetabek + Karawang1-2 hari kerja
Bali2-3 hari kerja
Bangka Belitung3-4 hari kerja
Banten1-3 hari kerja
Jawa Barat2-3 hari kerja
Jawa Tengah2-4 hari kerja
Jawa Timur2-4 hari kerja
Kalimantan3-7 hari kerja
Maluku3-10 hari kerja
Nanggroe Aceh Darussalam3-6 hari kerja
Nusa Tenggara3-6 hari kerja
Papua3-10 hari kerja
Sulawesi3-7 hari kerja
Sumatera + Kep. Riau3-6 hari kerja
Estimasi Pengiriman
SKU: SKU52978815

Telepon

0811 2244 828

WhatsApp

0811 2216 222

0

HANNA HI93414 Turbidity and Chlorine Meter

Description :

HI93414 is a high accuracy Turbidity and Chlorine Portable Meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI93414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.The chlorine measurements are are adapted EPA Method 330.5 and Standard Method 4500-Cl G.

Features :

Three Measurement Modes – The HI93414 features three options for measurement including ratio mode for turbidity, free chlorine, and total chlorine. Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range, while free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range
Multiple reading modes – Normal measurement, continuous measurement, or signal averaging measurement are reading modes available
EPA Compliant –  The HI93414 meets and exceeds the requirements of EPA and Standard Methods both for turbidity and colorimetric chlorine measurements. When the meter is in EPA mode all turbidity readings are rounded accordingly to meet reporting requirements
Calibration – A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.1, 15, 100, and 750 NTU) standards. Calibration points can be modified if user-prepared standards are used. For free and total chlorine, the 1.00 mg/L (ppm) CAL Check™ standard can be used for calibration and performance verification
AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.
CAL Check™  – With the powerful CAL Check™ function, reliable performance of the chlorine colorimeter can be validated at any moment by using the exclusive HANNA ready-made, NIST traceable standards.  All standards are supplied with a Certificate of Analysis (COA) for traceability
Fast Tracker™  – For advanced ˜field applications, the HI93414 is equipped with Fast Tracker™ – Tag Identi˜fication System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a speci˜fic measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identi˜cation code encased in stainless steel
GLP Data – The HI93414 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time
Data Logging – Up to 200 measurements can be stored in the internal memory and recalled at any time.
Data Transfer – For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB ports and the HI92000 software
Backlit Display – A backlit LCD display provides an easy to understand, user-friendly interface. Displayed codes guide the user step-by-step through routine operation and calibration
The HI98703 is a high accuracy (+0.02 NTU) Turbidity Portable Meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI98703 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.

Specifications :

Range : 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU
Resolution : 0.01; 0.1; 1 NTU
Range Selection : automatic
Accuracy : ±2% of reading plus 0.02 NTU
Repeatability : ±1% of reading or 0.02 NTU, whichever is greater
Stray Light : < 0.02 NTU
Light Detector : silicon photocell
Method : ratio nephelometric method (90° & 180°)
Measuring Mode : normal, average, continuous
Turbidity Standards : < 0.1, 15, 100, and 750 NTU
Calibration : two, three, or four-point calibration
Free and Total Chlorine Range : 0.00 to 5.00 mg/L (ppm)
Free and Total Chlorine Resolution : 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L (ppm); 0.10 above 3.50 mg/L (ppm)
Log Memory : 200 records
Connectivity : USB or RS232
Environment : 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply : 1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions : 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)
Weight : 512 g (18 oz.)

Includes :

Sample cuvettes and caps (5)
HI98703-11 calibration cuvettes for turbidity
HI93414-11 calibration cuvettes for chlorine
Silicone oil
Cuvette wiping cloth
Scissors
Batteries
AC adapter
Instruction manual
Rugged carrying case.

Turbidity Meter adalah salah satu alat umum yang biasa digunakan untuk keperluan analisa kekeruhan air atau larutan. Turbidity meter tu010merupakan alat pengujian kekeruan dengan sifat optik akibat dispersi sinar dan dapat dinyatakan sebagai perbandingan cahaya yang dipantulkan terhadap cahaya yang datang. Intensitas cahaya yang dipantulkan oleh suatu suspensi padatan adalah fungsi konsentrasi jika kondisi-kondisi lainnya konstan. Alat ini banyak digunakan dalam pengolahan air bersih untuk memastikan bahwa air yang akan digunakan memiliki kualitas yang baik dilihat dari tingkat kekeruhanya.

Update Jual HANNA HI93414 Turbidity and Chlorine Meter dengan harga murah dan garansi resmi dari distributor. Dapatkan produk terbaik dari merek HANNA dengan spesifikasi lengkap.

Belanja online TURBIDITY METER hanya di Kucari dengan kualitas terbaik, harga murah bersaing, bisa COD, Gratis pengiriman wilayah Jakarta dan sekitarnya. Beli sekarang hanya di toko online terpercaya.

Pengiriman ke seluruh Indonesia seperti Jakarta, Bandung, Bekasi, Depok, Cikarang, Tangerang, Lampung, Pontianak, Jogja, Semarang, Solo, Batam, Padang, Pekanbaru, Malang, Surabaya, Medan, Makassar, Balikpapan, Samarinda, Palembang, Riau, Aceh, Manado, NTT, NTB, Papua dan Bali Denpasar.

Specification: HANNA HI93414 Turbidity and Chlorine Meter

Berat 2 kg

User Reviews

0.0 out of 5
0
0
0
0
0
Write a review

There are no reviews yet.

Be the first to review “HANNA HI93414 Turbidity and Chlorine Meter”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

Q & A

There are no questions yet

Ask a question

Your question will be answered by a store representative or other customers.

Thank you for the question!

Mail

Your question has been received and will be answered soon. Please do not submit the same question again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

Add an answer

Thank you for the answer!

Mail

Your answer has been received and will be published soon. Please do not submit the same answer again.

Error

Warning

An error occurred when saving your question. Please report it to the website administrator. Additional information:

HANNA HI93414 Turbidity and Chlorine Meter
HANNA HI93414 Turbidity and Chlorine Meter
Jaminan 100% Aman

Kami menghadirkan pilihan metode pembayaran yang aman dan nyaman

Pengadaan Mudah

Proses pengadaan mudah & cepat +/- 5 menit, belanja online khusus bisnis

Jaminan Keaslian

Kucari.com menjamin produk yang kami jual 100% original berkualitas

Jaminan Pengiriman

Kami akan mengembalikan uang Anda secara penuh, jika barang tidak terkirim

Professional Support

Sales support Kucari.com siap membantu Anda melalui email, WA dan call center

Kucari.com

Kucari.com merupakan perusahaan B2B eCommerce yang berbasis di Indonesia untuk peralatan bisnis dan industri.

Peralatan industri Pertambangan, Minyak dan Gas, Konstruksi, Perkebunan dan Pertanian, Laboratorium dan Pendidikan, Horeka, Otomotif, MRO & industri lainnya.

Perusahaan

PT. INOVASI SUKSES SENTOSA

Business Park Kebon Jeruk Blok E2-8

JL. Meruya Ilir Raya No. 88
Kebon Jeruk Jakarta Barat 11620
Metode Pembayaran
Pilihan Pengiriman
Metode Pembayaran
Pilihan Pengiriman
© 2012-2021 Kucari.com - Indonesia B2B Ecommerce. All Rights Reserved.
Kucari.com
Logo
Register New Account
Reset Password
Shopping cart