FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER
Rp 130.650.000 *Inc. PPN
- Best temperature measurement accuracy
- Flexible configuration for the factory or benchtop
- Multiple modes of operation
- Real-time graphing in color
- Data portability and security
- Automated sensor calibration
[cresta-whatsapp-chat text=”Butuh bantuan? Whatsapp aja!” icon=”yes” position=”top” use=”number” number=””]
Sudah yakin dengan produk ini? Klik Tombol “Beli Sekarang”
*Harga tidak mengikat, sewaktu waktu bisa berubah tanpa pemberitahuan dahulu
Anda Perusahaan butuh penawaran harga resmi? Klik tombol “Penawaran Harga“
FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER
1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.
There are six key features that set the Super-DAQ apart from other products in its class:
- Best temperature measurement accuracy
- Flexible configuration for the factory or benchtop
- Multiple modes of operation
- Real-time graphing in color
- Data portability and security
- Automated sensor calibration
General Specifications |
|
| Mains Voltage | 100 V Setting: 90 V to 110 V 120 V Setting: 108 V to 132 V 220 V Setting: 198 V to 242 V 240 V Setting: 216 V to 264 V |
| Frequency | 47 Hz to 440 Hz |
| Power Consumption | 36 VA peak (24 W average) |
| Environment Temperature | Operating: 0 °C to 50 °C Full accuracy: 18 °C to 28 °C Storage: −20 °C to 70 °C Warm-up: 1 hour to full accuracy specifications |
| Relative Humidity (non-condensing) | Operating: 0 °C to 30 °C <80 %; 30 °C to 50 °C <50 % Storage: −20 °C to 70 °C <95 % |
| Altitude | Operating: 2,000 m Storage: 12,000 m |
| Vibration and Shock | Complies with MIL-PRF-28800F Class 3 |
| Channel Capacity | Total analog channels: 45 Voltage/resistance channels: 41 Current channels: 5 Digital I/O: 8 bits Totalizer: 1 Alarm outputs: 6 Trigger input: 1 |
| Input Protection | 50 V all functions, terminals and ranges |
| Math Channels | Number of channels: 20 Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum |
| Triggers | interval, external (trigger input), alarm, remote (bus), manual, automated test |
| Memory | Scan data RAM: 75,000 readings with timestamp Data/Setup flash memory: 20 MB |
| USB Host Port | Connector type: Type A Function: Memory File system: FAT32 Memory capacity: 32 GB |
| USB Device Port | Connector type: Type B Class: Instrument Function: Control and data transfer Command protocol: SCPI |
| LAN | Function: Control and data transfer Network protocols: Ethernet 10/100, TCP/IP Command protocol: SCPI |
| RS-232 | Connector: D-sub 9 pin (DE-9) Baud rates: 1200, 2400, 4800, 9600, 19200, 38400 Function: Temperature source control output |
| Dimensions | Height: 150 mm Width: 245 mm Depth: 385 mm Weight: 6 kg (typical configuration) Shipping Weight: 9.5 kg (typical configuration) |
| Conformity | CE, CSA, IEC 61010 3rd ed. |
Measurement Specifications |
|
| Accuracy specifications generally apply with medium and slow sample rates (unless otherwise noted), after a warm-up time of 1 hour, and within an environment temperature range of 18 °C to 28 °C, and may depend on the channel. The confidence level for accuracy specifications is 95 % within 1 year of calibration. | |
| Scan rate | Fast: 10 channels per second max (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel) Slow: 4 seconds per channel |
| Display Resolution | 6 1/2 digits (see Measurement Characteristics tables below to find the display resolution of temperature readings) |
PRT/RTD |
|
| Temperature Range | −200 °C to 1200 °C (depending on the sensor) |
| Resistance Range | 0 Ω to 4 kΩ |
| Offset Compensation | 0 Ω to 400 Ω, 4-wire: automatic current reversal 400 Ω to 4000 Ω or 3-wire: none |
| Source Current Reversal Interval (0 Ω to 400 Ω range) | Fast sample rate: 2 ms Medium sample rate: 250 ms Slow sample rate: 250 ms |
| Maximum Lead Resistance (4-wire Ω) | 2.5 % of range per lead for 400 Ω and 4 kΩ ranges |
PRT/RTD Resistance Accuracy |
||||
| Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using 3-wire PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.05 Ω if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. | ||||
| Range | Sample Rate | DAQ-STAQ Module and Channel 1 | High-Capacity Module | T.C./ °C Outside 18 °C to 28 °C |
| 0 Ω to 400 Ω | Slow | 0.002 % or 0.0008 Ω | 0.003 % or 0.003 Ω | 0.0001 % or 0.0008 Ω |
| Medium | 0.002 % or 0.002 Ω | 0.003 % or 0.003 Ω | 0.0001 % or 0.0008 Ω | |
| Fast | 0.002 % or 0.005 Ω | 0.003 % or 0.006 Ω | 0.0001 % or 0.0008 Ω | |
| 400 Ω to 4 kΩ | Slow | 0.004 % or 0.06 Ω | 0.006 % or 0.06 Ω | 0.0001 % or 0.008 Ω |
| Medium | 0.004 % or 0.1 Ω | 0.006 % or 0.1 Ω | 0.0001 % or 0.008 Ω | |
| Fast | 0.004 % or 0.18 Ω | 0.006 % or 0.18 Ω | 0.0001 % or 0.008 Ω | |
PRT/RTD Temperature Accuracy |
||||
| Accuracy is for 4-wire 100 Ω nominal PRT/RTD. When using 3-wire PRT/RTD add 0.039 °C to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient number by the temperature deviation and add to the accuracy specification. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor and characterization. | ||||
| Sample Rate | Temperature | DAQ-STAQ Module and Channel 1 | High-Capacity Module | T.C./ °C Outside 18 °C to 28 °C |
| Slow | −200 °C | 0.002 °C | 0.008 °C | 0.002 °C |
| 0 °C | 0.005 °C | 0.008 °C | 0.003 °C | |
| 300 °C | 0.012 °C | 0.018 °C | 0.006 °C | |
| 600 °C | 0.02 °C | 0.03 °C | 0.01 °C | |
| Medium | −200 °C | 0.005 °C | 0.008 °C | 0.002 °C |
| 0 °C | 0.005 °C | 0.008 °C | 0.003 °C | |
| 300 °C | 0.012 °C | 0.018 °C | 0.006 °C | |
| 600 °C | 0.02 °C | 0.03 °C | 0.01 °C | |
| Fast | −200 °C | 0.013 °C | 0.015 °C | 0.002 °C |
| 0 °C | 0.013 °C | 0.015 °C | 0.003 °C | |
| 300 °C | 0.014 °C | 0.018 °C | 0.006 °C | |
| 600 °C | 0.02 °C | 0.03 °C | 0.01 °C | |
PRT/RTD Measurement Characteristics |
|||
| Temperature Display Resolution | |||
| Range | Slow / Medium Sample Rate | Fast Sample Rate | Source Current |
| 0 Ω to 400 Ω | 0.001 °C | 0.01 °C | ±1 mA |
| 400 Ω to 4 kΩ | 0.001 °C | 0.01 °C | 0.1 mA |
Thermistor |
||||
| Temperature Range | −200 °C to 400 °C (depending on the sensor) | |||
| Resistance Range | 0 Ω to 1 MΩ | |||
Thermistor Resistance Accuracy |
||||
| Accuracy is given as ± (% of measurement + Ω). The basic accuracy specification is for 4-wire thermistor, slow sample rate. When using medium or fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. For 2-wire thermistor add 0.02 Ω internal resistance if using Channel 1 or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. |
||||
| Range | Slow Sample Rate | Medium Sample Rate Rate | Fast Sample Rate | T.C./ °C Outside18 °C to 28 °C |
| 0 Ω to 2.2 kΩ | 0.004 % + 0.2 Ω | add 0.3 Ω | add 1 Ω | 0.0005 % + 0.05 Ω |
| 2.1 kΩ to 98 kΩ | 0.004 % + 0.5 Ω | add 0.5 Ω | add 1.3 Ω | 0.0005 % + 0.1 Ω |
| 95 kΩ to 1 MΩ | 0.015 % + 5 Ω | add 5 Ω | add 13 Ω | 0.001 % + 2 Ω |
Thermistor Temperature Accuracy |
||||
| Accuracy specifications are for 4-wire thermistor. When using 2-wire thermistor, add the number given in the table to the specification for internal resistance. If the environment temperature is outside the specified range, increase the accuracy specification by 25 % for every 1 °C outside the specified environment temperature range. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor. | ||||
| Accuracy 2.2 Ω Thermistor | ||||
| Temperature | SlowSample Rate | MediumSample Rate | FastSample Rate | 2-wire |
| −40 °C | 0.001 °C | 0.001 °C | 0.01 °C | add 0.001 °C |
| 0 °C | 0.003 °C | 0.004 °C | 0.01 °C | add 0.004 °C |
| 25 °C | 0.006 °C | 0.011 °C | 0.02 °C | add 0.016 °C |
| 50 °C | 0.008 °C | 0.018 °C | 0.04 °C | add 0.05 °C |
| 100 °C | 0.047 °C | 0.114 °C | 0.28 °C | add 0.34 °C |
| 150 °C | 0.23 °C | 0.56 °C | 1.34 °C | add 1.7 °C |
| Accuracy 5 Ω Thermistor | ||||
| Temperature | Slow Sample Rate | Medium Sample Rate | Fast Sample Rate | 2-wire |
| −40 °C | 0.003 °C | 0.004 °C | 0.01 °C | add 0.001 °C |
| 0 °C | 0.002 °C | 0.002 °C | 0.01 °C | add 0.002 °C |
| 25 °C | 0.004 °C | 0.006 °C | 0.01 °C | add 0.007 °C |
| 50 °C | 0.005 °C | 0.009 °C | 0.02 °C | add 0.022 °C |
| 100 °C | 0.022 °C | 0.052 °C | 0.13 °C | add 0.16 °C |
| 150 °C | 0.096 °C | 0.24 °C | 0.57 °C | add 0.7 °C |
| Accuracy 10 Ω Thermistor | ||||
| Temperature | Slow Sample Rate | Medium Sample Rate | Fast Sample Rate | 2-wire |
| −40 °C | 0.003 °C | 0.004 °C | 0.01 °C | add 0.001 °C |
| 0 °C | 0.002 °C | 0.002 °C | 0.01 °C | add 0.002 °C |
| 25 °C | 0.003 °C | 0.004 °C | 0.01 °C | add 0.004 °C |
| 50 °C | 0.005 °C | 0.009 °C | 0.02 °C | add 0.011 °C |
| 100 °C | 0.011 °C | 0.024 °C | 0.06 °C | add 0.067 °C |
| 150 °C | 0.04 °C | 0.098 °C | 0.24 °C | add 0.29 °C |
Thermistor Measurement Characteristics |
|||
| Temperature Display Resolution | |||
| Range | Slow / Medium Sample Rate |
Fast Sample Rate |
Source Current |
| 0 Ω to 2.2 Ω | 0.0001 °C | 0.001 °C | 10 μA |
| 2.1 Ω to 98 Ω | 0.0001 °C | 0.001 °C | 10 μA |
| 95 Ω to 1 MΩ | 0.0001 °C | 0.001 °C | 1 μA |
Thermocouple |
||||
| Temperature Range | −270 °C to 2315 °C (depending on the sensor) | |||
| Voltage Range | −15 mV to 100 mV | |||
Thermocouple Voltage Accuracy |
||||
| Accuracy is given as ± (|% of measurement| + μV). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. | ||||
| Range | Accuracy Channel 1 | Ch. x01 – x20 | Fast Sample Rate | T.C./ °C Outside 18 °C to 28 °C |
| −15 mV to 100 mV | 0.004 % + 4 μV | add 2 μV | add 1 μV | 0.0005 % + 0.0005 mV |
Thermocouple Reference Junction Accuracy |
||
|
Module |
CJC Accuracy |
T.C./ °C Outside 18 °C to 28 °C |
| DAQ-STAQ Module |
0.25 °C |
0.02 °C |
| High-Capacity Module |
0.6 °C |
0.05 °C |
Thermocouple Temperature Accuracy |
|||||
| Accuracy specifications apply using medium or slow sample rate. When using fast sample rate, increase the accuracy specification by 25 %. If the environment temperature is outside the specified range, increase the accuracy specification by 12 % for every 1 °C outside the specified environment temperature range. Accuracy with fixed/external CJC does not include the accuracy of the reference junction temperature. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor. | |||||
| Type (Range) |
Temperature | Accuracy | |||
| Fixed / External CJC | Internal CJC | ||||
| Channel 1 | Ch. x01 – x20 | DAQ-STAQ Module | High-Capacity Module |
||
| K −270 °C to 1372 °C |
−200 °C 0 °C 1000 °C |
0.28 °C 0.10 °C 0.14 °C |
0.41 °C 0.15 °C 0.20 °C |
0.76 °C 0.29 °C 0.32 °C |
1.60 °C 0.62 °C 0.64 °C |
| T −270 °C to 400 °C |
−200 °C 0 °C 200 °C 400 °C |
0.27 °C 0.10 °C 0.08 °C 0.08 °C |
0.40 °C 0.15 °C 0.12 °C 0.11 °C |
0.76 °C 0.30 °C 0.23 °C 0.20 °C |
1.60 °C 0.65 °C 0.47 °C 0.41 °C |
| R −50 °C to 1768 °C |
0 °C 300 °C 1200 °C 1600 °C |
0.76 °C 0.42 °C 0.33 °C 0.34 °C |
1.13 °C 0.63 °C 0.47 °C 0.49 °C |
1.16 °C 0.64 °C 0.48 °C 0.50 °C |
1.28 °C 0.71 °C 0.52 °C 0.54 °C |
| S −50 °C to 1768 °C |
0 °C 300 °C 1200 °C 1600 °C |
0.74 °C 0.45 °C 0.37 °C 0.39 °C |
1.11 °C 0.67 °C 0.54 °C 0.56 °C |
1.14 °C 0.68 °C 0.55 °C 0.57 °C |
1.26 °C 0.76 °C 0.60 °C 0.63 °C |
| J −210 °C to 1200 °C |
−200 °C 0 °C 1000 °C |
0.20 °C 0.08 °C 0.11 °C |
0.29 °C 0.12 °C 0.14 °C |
0.65 °C 0.28 °C 0.25 °C |
1.41 °C 0.61 °C 0.53 °C |
| N −270 °C to 1300 °C |
−200 °C 0 °C 500 °C 1000 °C |
0.42 °C 0.15 °C 0.12 °C 0.14 °C |
0.62 °C 0.23 °C 0.17 °C 0.19 °C |
0.90 °C 0.34 °C 0.24 °C 0.26 °C |
1.69 °C 0.64 °C 0.44 °C 0.45 °C |
| E −270 °C to 1000 °C |
−200 °C 0 °C 300 °C 700 °C |
0.17 °C 0.07 °C 0.06 °C 0.08 °C |
0.25 °C 0.10 °C 0.09 °C 0.10 °C |
0.64 °C 0.27 °C 0.21 °C 0.21 °C |
1.42 °C 0.61 °C 0.46 °C 0.45 °C |
| B 100 °C to 1820 °C |
300 °C 600 °C 1200 °C 1600 °C |
1.32 °C 0.68 °C 0.41 °C 0.38 °C |
1.97 °C 1.02 °C 0.60 °C 0.55 °C |
1.97 °C 1.02 °C 0.60 °C 0.55 °C |
1.97 °C 1.02 °C 0.60 °C 0.55 °C |
| C 0 °C to 2315 °C |
600 °C 1200 °C 2000 °C |
0.23 °C 0.28 °C 0.44 °C |
0.33 °C 0.40 °C 0.60 °C |
0.37 °C 0.45 °C 0.66 °C |
0.54 °C 0.63 °C 0.91 °C |
| D 0 °C to 2315 °C |
600 °C 1200 °C 2000 °C |
0.22 °C 0.26 °C 0.39 °C |
0.32 °C 0.36 °C 0.53 °C |
0.34 °C 0.39 °C 0.56 °C |
0.44 °C 0.49 °C 0.69 °C |
| G 0 °C to 2315 °C |
600 °C 1200 °C 2000 °C |
0.24 °C 0.22 °C 0.33 °C |
0.36 °C 0.32 °C 0.46 °C |
0.36 °C 0.32 °C 0.46 °C |
0.36 °C 0.33 °C 0.46 °C |
| L −200 °C to 900 °C |
−200 °C 0 °C 800 °C |
0.13 °C 0.08 °C 0.09 °C |
0.19 °C 0.12 °C 0.12 °C |
0.45 °C 0.28 °C 0.23 °C |
0.99 °C 0.62 °C 0.48 °C |
| M −50 °C to 1410 °C |
0 °C 500 °C 1000 °C |
0.11 °C 0.10 °C 0.10 °C |
0.16 °C 0.15 °C 0.14 °C |
0.30 °C 0.25 °C 0.21 °C |
0.64 °C 0.51 °C 0.41 °C |
| U −200 °C to 600 °C |
−200 °C 0 °C 400 °C |
0.25 °C 0.10 °C 0.08 °C |
0.37 °C 0.15 °C 0.11 °C |
0.71 °C 0.30 °C 0.20 °C |
1.48 °C 0.63 °C 0.40 °C |
| W 0 °C to 2315 °C |
600 °C 1200 °C 2000 °C |
0.24 °C 0.22 °C 0.33 °C |
0.36 °C 0.32 °C 0.46 °C |
0.36 °C 0.32 °C 0.46 °C |
0.36 °C 0.33 °C 0.46 °C |
Thermocouple Measurement Characteristics |
||
| Range | Temperature Display Resolution | |
| Slow / Medium Sample Rate |
Fast Sample Rate |
|
| −270 °C to 2315 °C | 0.01 °C | 0.1 °C |
DC Voltage |
||||
| Maximum Input | 50 V on any range | |||
| Common Mode Rejection | 140 dB at 50 Hz or 60 Hz (1 kΩ unbalance in LOW lead) ±50 V peak maximum | |||
| Normal Mode Rejection | 55 dB for power line frequency ±0.1 %, ±120 % of range peak maximum | |||
| A/D Linearity | 2 ppm of measurement + 1 ppm of range | |||
| Input Bias Current | 30 pA at 25 °C | |||
DC Voltage Accuracy |
||||
| Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1, medium or slow sample rate. For channels x01 through x20 or when using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. | ||||
| Range | Accuracy Channel 1 | Ch. x01 – x20 | Fast Sample Rate | T.C./ °C Outside 18 °C to 28 °C |
| ±100 mV | 0.0037 % + 0.0035 % | add 2 μ | add 0.0008 % of range | 0.0005 % + 0.0005 % |
| ±1 V | 0.0025 % + 0.0007 % | add 2 μ | add 0.0008 % of range | 0.0005 % + 0.0001 % |
| ±10 V | 0.0024 % + 0.0005 % | − | add 0.0008 % of range | 0.0005 % + 0.0001 % |
| ±50 V | 0.0038 % + 0.0012 % | − | add 0.0008 % of range | 0.0005 % + 0.0001 % |
DC Voltage Input Characteristics |
||||
| Resolution | Input Impedance | |||
| Range | Slow / Medium | Fast | ||
| ±100 mV | 0.1 μ | 1 μ | 10 GΩ [1] | |
| ±1 V | 1 μ | 10 μ | 10 GΩ [1] | |
| ±10 V | 10 μ | 100 μ | 10 GΩ [1] | |
| ±50 V | 100 μ | 1 mV | 10 MΩ ±1 % | |
| [1] – Input beyond ±12 V is clamped. The clamp current is up to 3 mA. | ||||
DC Current |
|||
| Input Protection | 0.15 A resettable PTC | ||
DC Current Accuracy |
|||
| Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. | |||
| Range | Accuracy | Fast Sample Rate | T.C./ °C Outside 18 °C to 28 °C |
| ±100 μA | 0.015 % + 0.0035 % | add 0.0008 % of range | 0.002 % + 0.001 % |
| ±1 mA | 0.015 % + 0.0011 % | add 0.0008 % of range | 0.002 % + 0.001 % |
| ±10 mA | 0.015 % + 0.0035 % | add 0.0008 % of range | 0.002 % + 0.001 % |
| ±100 mA | 0.015 % + 0.0035 % | add 0.0008 % of range | 0.002 % + 0.001 % |
DC Current Input Characteristics |
|||
| Resolution | |||
| Range | Slow / Medium | Fast | Burden Voltage |
| ±100 μA | 0.1 nA | 1 nA | <1 mV |
| ±1 mA | 1 nA | 10 nA | <1 mV |
| ±10 mA | 10 nA | 100 nA | <1 mV |
| ±100 mA | 100 nA | 1 μA | <1 mV |
Resistance |
|||
| Max. Lead Resistance (4-wire ohms) | 10 Ω per lead for 100 Ω and 1 kΩ ranges. 1 kΩ per lead on all other ranges. | ||
Resistance Accuracy |
|||
| Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for 4-wire resistance, medium or slow sample rate. For 2-wire resistance add 0.02 Ω internal resistance if using Channel 1, or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. When using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the Temperature Coefficient numbers by the temperature deviation and add to the accuracy specification | |||
| Range | Accuracy | Fast Sample Rate | 1T.C./ °C Outside 8 °C to 28 °C |
| 100 Ω | 0.004 % + 0.0035 % | add 0.001 % of range | 0.0001 % + 0.0005 % |
| 1 kΩ | 0.003 % + 0.001 % | add 0.001 % of range | 0.0001 % + 0.0001 % |
| 10 kΩ | 0.004 % + 0.001 % | add 0.001 % of range | 0.0001 % + 0.0001 % |
| 100 kΩ | 0.004 % + 0.001 % | add 0.001 % of range | 0.0001 % + 0.0001 % |
| 1 MΩ | 0.006 % + 0.001 % | add 0.002 % of reading plus 0.0008 % of range | 0.0005 % + 0.0002 % |
| 10 MΩ | 0.015 % + 0.001 % | add 0.002 % of reading plus 0.0008 % of range | 0.001 % + 0.0004 % |
| 100 MΩ | 0.8 % + 0.01 % | add 0.01 % of range | 0.05 % + 0.002 % |
Resistance Input Characteristics |
|||
| Range | Resolution Slow / Medium |
Fast | Source Current (open-circuit voltage) |
| 100 Ω | 0.1 mΩ | 1 mΩ | 1 mA (4 V) |
| 1 kΩ | 1 mΩ | 10 mΩ | 1 mA (4 V) |
| 10 kΩ | 10 mΩ | 100 mΩ | 100 μA (6 V) |
| 100 kΩ | 100 mΩ | 1 Ω | 100 μA (12 V) |
| 1 MΩ | 1 Ω | 10 Ω | 10 μA (12 V) |
| 10 MΩ | 10 Ω | 100 Ω | 1 μA (12 V) |
| 100 MΩ | 100 Ω | 1 kΩ | 0.1 μA (12 V) |
Digital I/O |
|
| Absolute Voltage Range | –4 V to 30 V |
| Input Minimum Logic High | 2.0 V |
| Input Maximum Logic Low | 0.7 V |
| Output Type | open drain active low |
| Output Logic Low (<1 mA) | 0 V to 0.7 V |
| Maximum Sink Current | 50 mA |
| Output Resistance | 47 Ω |
Totalizer |
|
| Absolute Voltage Range | –4 V to 30 V |
| Minimum Logic High | 2.0 V |
| Maximum Logic Low | 0.7 V |
| Minimum Pulse Width | 50 μs |
| Maximum Frequency | 10 kHz |
| Debounce Time | 1.7 ms |
| Maximum Count | 1048575 (20 bits) |
Trigger |
|
| Absolute Voltage Range | –4 V to 30 V |
| Minimum Logic High | 2.0 V |
| Maximum Logic Low | 0.7 V |
| Minimum Pulse Width | 50 μs |
| Maximum Latency | 100 ms |
Alarm Output |
|
| Absolute Voltage Range | –4 V to 30 V |
| Output Type | open drain active low |
| Output Logic Low (<1 mA) | 0 V to 0.7 V |
| Maximum Sink Current | 50 mA |
| Output Resistance | 47 Ω |
1586-2588 DAQ-STAQ Input Module Specifications |
|
| Maximum Input | 50 V |
| Offset Voltage | <2 μV |
| 3-Wire Internal Resistance Mismatch | <50 mΩ |
| Basic CJC Accuracy | 0.25 °C |
1586-2586 High-Capacity Input Module Specifications |
|
| Maximum Input | 50 V |
| Offset Voltage | <2 μV |
| 3-Wire Internal Resistance Mismatch | <50 mΩ |
| Basic CJC Accuracy | 0.6 °C |
Jual FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER Dengan Harga murah dan cari produk terbaik lainnya dari kategori dari Thermometer Merek FLUKE Gratis biaya pengiriman untuk wilayah Jakarta dan dapat dikirim ke seluruh Indonesia. Dapatkan hanya di toko online Kucari.com, belanja online alat ukur dan alat survey mudah dan aman.
Kucari.com menyediakan berbagai alat ukur dan instruments dari supplier dan distributor resmi yang tersebar dibeberapa kota di Indonesia seperti Jakarta, Bandung, Bekasi, Depok, Cikarang, Tangerang, Lampung, Pontianak, Jogja, Semarang, Solo, Batam, Padang, Pekanbaru, Malang, Surabaya, Medan, Makassar, Balikpapan, Samarinda, Pelembang, Riau, Aceh, Manado, dan Bali.
Daftarkan perusahaan Anda!
Anda adalah Agen, Vendor, Supplier & Distributor peralatan ukur dan perkakas untuk wilayah Indonesia? Daftarkan perusahaan Anda disini
Kucari.com merupakan situs penyedia direktori peralatan dan perkakas bisnis sebagai media promosi online berbasis web yang dapat menghubungkan supplier, distributor, agen, vendor dan pembeli antar bisnis (B2B – Business to Business) dan kalangan B2C (Business-to-Customer) dalam 24 Jam nonstop menjangkau seluruh wilayah Indonesia .
User Reviews
Be the first to review “FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER”
Rp 130.650.000 *Inc. PPN

There are no reviews yet.