FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER

Brands:Fluke

Dijual & dikirim oleh: Kucari.com
  • Best temperature measurement accuracy
  • Flexible configuration for the factory or benchtop
  • Multiple modes of operation
  • Real-time graphing in color
  • Data portability and security
  • Automated sensor calibration

[cresta-whatsapp-chat text=”Butuh bantuan? Whatsapp aja!” icon=”yes” position=”top” use=”number” number=””]

Sudah yakin dengan produk ini? Klik Tombol “Beli Sekarang”
*Harga tidak mengikat, sewaktu waktu bisa berubah tanpa pemberitahuan dahulu

Anda Perusahaan butuh penawaran harga resmi? Klik tombol “Penawaran Harga

FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER

1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.

There are six key features that set the Super-DAQ apart from other products in its class:

  • Best temperature measurement accuracy
  • Flexible configuration for the factory or benchtop
  • Multiple modes of operation
  • Real-time graphing in color
  • Data portability and security
  • Automated sensor calibration

 

General Specifications

Mains Voltage 100 V Setting: 90 V to 110 V
120 V Setting: 108 V to 132 V
220 V Setting: 198 V to 242 V
240 V Setting: 216 V to 264 V
Frequency 47 Hz to 440 Hz
Power Consumption 36 VA peak (24 W average)
Environment Temperature Operating: 0 °C to 50 °C
Full accuracy: 18 °C to 28 °C
Storage: −20 °C to 70 °C
Warm-up: 1 hour to full accuracy specifications
Relative Humidity (non-condensing) Operating: 0 °C to 30 °C <80 %;
30 °C to 50 °C <50 %
Storage: −20 °C to 70 °C <95 %
Altitude Operating: 2,000 m
Storage: 12,000 m
Vibration and Shock Complies with MIL-PRF-28800F Class 3
Channel Capacity Total analog channels: 45
Voltage/resistance channels: 41
Current channels: 5
Digital I/O: 8 bits
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Input Protection 50 V all functions, terminals and ranges
Math Channels Number of channels: 20
Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
Triggers interval, external (trigger input), alarm, remote (bus), manual, automated test
Memory Scan data RAM: 75,000 readings with timestamp
Data/Setup flash memory: 20 MB
USB Host Port Connector type: Type A
Function: Memory
File system: FAT32
Memory capacity: 32 GB
USB Device Port Connector type: Type B
Class: Instrument
Function: Control and data transfer
Command protocol: SCPI
LAN Function: Control and data transfer
Network protocols: Ethernet 10/100, TCP/IP
Command protocol: SCPI
RS-232 Connector: D-sub 9 pin (DE-9)
Baud rates: 1200, 2400, 4800, 9600, 19200, 38400
Function: Temperature source control output
Dimensions Height: 150 mm
Width: 245 mm
Depth: 385 mm Weight: 6 kg (typical configuration)
Shipping Weight: 9.5 kg (typical configuration)
Conformity CE, CSA, IEC 61010 3rd ed.

 

Measurement Specifications

Accuracy specifications generally apply with medium and slow sample rates (unless otherwise noted), after a warm-up time of 1 hour, and within an environment temperature range of 18 °C to 28 °C, and may depend on the channel. The confidence level for accuracy specifications is 95 % within 1 year of calibration.
Scan rate Fast: 10 channels per second max (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel)
Slow: 4 seconds per channel
Display Resolution 6 1/2 digits (see Measurement Characteristics tables below to find the display resolution of temperature readings)

 

PRT/RTD

Temperature Range −200 °C to 1200 °C (depending on the sensor)
Resistance Range 0 Ω to 4 kΩ
Offset Compensation 0 Ω to 400 Ω, 4-wire: automatic current reversal
400 Ω to 4000 Ω or 3-wire: none
Source Current Reversal Interval (0 Ω to 400 Ω range) Fast sample rate: 2 ms
Medium sample rate: 250 ms
Slow sample rate: 250 ms
Maximum Lead Resistance (4-wire Ω) 2.5 % of range per lead for 400 Ω and 4 kΩ ranges

 

PRT/RTD Resistance Accuracy

Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using 3-wire PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.05 Ω if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Sample Rate DAQ-STAQ Module and Channel 1 High-Capacity Module T.C./ °C Outside 18 °C to 28 °C
0 Ω to 400 Ω Slow 0.002 % or 0.0008 Ω 0.003 % or 0.003 Ω 0.0001 % or 0.0008 Ω
Medium 0.002 % or 0.002 Ω 0.003 % or 0.003 Ω 0.0001 % or 0.0008 Ω
Fast 0.002 % or 0.005 Ω 0.003 % or 0.006 Ω 0.0001 % or 0.0008 Ω
400 Ω to 4 kΩ Slow 0.004 % or 0.06 Ω 0.006 % or 0.06 Ω 0.0001 % or 0.008 Ω
Medium 0.004 % or 0.1 Ω 0.006 % or 0.1 Ω 0.0001 % or 0.008 Ω
Fast 0.004 % or 0.18 Ω 0.006 % or 0.18 Ω 0.0001 % or 0.008 Ω

 

PRT/RTD Temperature Accuracy

Accuracy is for 4-wire 100 Ω nominal PRT/RTD. When using 3-wire PRT/RTD add 0.039 °C to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient number by the temperature deviation and add to the accuracy specification. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor and characterization.
Sample Rate Temperature DAQ-STAQ Module and Channel 1 High-Capacity Module T.C./ °C Outside 18 °C to 28 °C
Slow −200 °C 0.002 °C 0.008 °C 0.002 °C
0 °C 0.005 °C 0.008 °C 0.003 °C
300 °C 0.012 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
Medium −200 °C 0.005 °C 0.008 °C 0.002 °C
0 °C 0.005 °C 0.008 °C 0.003 °C
300 °C 0.012 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C
Fast −200 °C 0.013 °C 0.015 °C 0.002 °C
0 °C 0.013 °C 0.015 °C 0.003 °C
300 °C 0.014 °C 0.018 °C 0.006 °C
600 °C 0.02 °C 0.03 °C 0.01 °C

 

PRT/RTD Measurement Characteristics

Temperature Display Resolution
Range Slow / Medium Sample Rate Fast Sample Rate Source Current
0 Ω to 400 Ω 0.001 °C 0.01 °C ±1 mA
400 Ω to 4 kΩ 0.001 °C 0.01 °C 0.1 mA

 

Thermistor

Temperature Range −200 °C to 400 °C (depending on the sensor)
Resistance Range 0 Ω to 1 MΩ

 

Thermistor Resistance Accuracy

Accuracy is given as ± (% of measurement + Ω). The basic accuracy specification is for 4-wire thermistor, slow sample rate. When using medium or fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. For 2-wire thermistor add 0.02 Ω internal resistance if using Channel 1 or
1.5 Ω if using channels x01 through x20, and add external lead wire resistance.
Range Slow Sample Rate Medium Sample Rate Rate Fast Sample Rate T.C./ °C Outside18 °C to 28 °C
0 Ω to 2.2 kΩ 0.004 % + 0.2 Ω add 0.3 Ω add 1 Ω 0.0005 % + 0.05 Ω
2.1 kΩ to 98 kΩ 0.004 % + 0.5 Ω add 0.5 Ω add 1.3 Ω 0.0005 % + 0.1 Ω
95 kΩ to 1 MΩ 0.015 % + 5 Ω add 5 Ω add 13 Ω 0.001 % + 2 Ω

 

Thermistor Temperature Accuracy

Accuracy specifications are for 4-wire thermistor. When using 2-wire thermistor, add the number given in the table to the specification for internal resistance. If the environment temperature is outside the specified range, increase the accuracy specification by 25 % for every 1 °C outside the specified environment temperature range. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor.
Accuracy 2.2 Ω Thermistor
Temperature SlowSample Rate MediumSample Rate FastSample Rate 2-wire
−40 °C 0.001 °C 0.001 °C 0.01 °C add 0.001 °C
0 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
25 °C 0.006 °C 0.011 °C 0.02 °C add 0.016 °C
50 °C 0.008 °C 0.018 °C 0.04 °C add 0.05 °C
100 °C 0.047 °C 0.114 °C 0.28 °C add 0.34 °C
150 °C 0.23 °C 0.56 °C 1.34 °C add 1.7 °C
Accuracy 5 Ω Thermistor
Temperature Slow Sample Rate Medium Sample Rate Fast Sample Rate 2-wire
−40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
25 °C 0.004 °C 0.006 °C 0.01 °C add 0.007 °C
50 °C 0.005 °C 0.009 °C 0.02 °C add 0.022 °C
100 °C 0.022 °C 0.052 °C 0.13 °C add 0.16 °C
150 °C 0.096 °C 0.24 °C 0.57 °C add 0.7 °C
Accuracy 10 Ω Thermistor
Temperature Slow Sample Rate Medium Sample Rate Fast Sample Rate 2-wire
−40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
25 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
50 °C 0.005 °C 0.009 °C 0.02 °C add 0.011 °C
100 °C 0.011 °C 0.024 °C 0.06 °C add 0.067 °C
150 °C 0.04 °C 0.098 °C 0.24 °C add 0.29 °C

 

Thermistor Measurement Characteristics

Temperature Display Resolution
Range Slow / Medium
Sample Rate
Fast
Sample Rate
Source Current
0 Ω to 2.2 Ω 0.0001 °C 0.001 °C 10 μA
2.1 Ω to 98 Ω 0.0001 °C 0.001 °C 10 μA
95 Ω to 1 MΩ 0.0001 °C 0.001 °C 1 μA

 

Thermocouple

Temperature Range −270 °C to 2315 °C (depending on the sensor)
Voltage Range −15 mV to 100 mV

 

Thermocouple Voltage Accuracy

Accuracy is given as ± (|% of measurement| + μV). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Channel 1 Ch. x01 – x20 Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
−15 mV to 100 mV 0.004 % + 4 μV add 2 μV add 1 μV 0.0005 % + 0.0005 mV

 

Thermocouple Reference Junction Accuracy

 

Module

 

CJC Accuracy

T.C./ °C Outside
18 °C to 28 °C
DAQ-STAQ Module

0.25 °C

0.02 °C

High-Capacity Module

0.6 °C

0.05 °C

 

Thermocouple Temperature Accuracy

Accuracy specifications apply using medium or slow sample rate. When using fast sample rate, increase the accuracy specification by 25 %. If the environment temperature is outside the specified range, increase the accuracy specification by 12 % for every 1 °C outside the specified environment temperature range. Accuracy with fixed/external CJC does not include the accuracy of the reference junction temperature. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor.
Type
(Range)
Temperature Accuracy
Fixed / External CJC Internal CJC
Channel 1 Ch. x01 – x20 DAQ-STAQ Module High-Capacity
Module
K
−270 °C to
1372 °C
−200 °C
0 °C
1000 °C
0.28 °C
0.10 °C
0.14 °C
0.41 °C
0.15 °C
0.20 °C
0.76 °C
0.29 °C
0.32 °C
1.60 °C
0.62 °C
0.64 °C
T
−270 °C to
400 °C
−200 °C
0 °C
200 °C
400 °C
0.27 °C
0.10 °C
0.08 °C
0.08 °C
0.40 °C
0.15 °C
0.12 °C
0.11 °C
0.76 °C
0.30 °C
0.23 °C
0.20 °C
1.60 °C
0.65 °C
0.47 °C
0.41 °C
R
−50 °C to
1768 °C
0 °C
300 °C
1200 °C
1600 °C
0.76 °C
0.42 °C
0.33 °C
0.34 °C
1.13 °C
0.63 °C
0.47 °C
0.49 °C
1.16 °C
0.64 °C
0.48 °C
0.50 °C
1.28 °C
0.71 °C
0.52 °C
0.54 °C
S
−50 °C to
1768 °C
0 °C
300 °C
1200 °C
1600 °C
0.74 °C
0.45 °C
0.37 °C
0.39 °C
1.11 °C
0.67 °C
0.54 °C
0.56 °C
1.14 °C
0.68 °C
0.55 °C
0.57 °C
1.26 °C
0.76 °C
0.60 °C
0.63 °C
J
−210 °C to
1200 °C
−200 °C
0 °C
1000 °C
0.20 °C
0.08 °C
0.11 °C
0.29 °C
0.12 °C
0.14 °C
0.65 °C
0.28 °C
0.25 °C
1.41 °C
0.61 °C
0.53 °C
N
−270 °C to
1300 °C
−200 °C
0 °C
500 °C
1000 °C
0.42 °C
0.15 °C
0.12 °C
0.14 °C
0.62 °C
0.23 °C
0.17 °C
0.19 °C
0.90 °C
0.34 °C
0.24 °C
0.26 °C
1.69 °C
0.64 °C
0.44 °C
0.45 °C
E
−270 °C to
1000 °C
−200 °C
0 °C
300 °C
700 °C
0.17 °C
0.07 °C
0.06 °C
0.08 °C
0.25 °C
0.10 °C
0.09 °C
0.10 °C
0.64 °C
0.27 °C
0.21 °C
0.21 °C
1.42 °C
0.61 °C
0.46 °C
0.45 °C
B
100 °C to
1820 °C
300 °C
600 °C
1200 °C
1600 °C
1.32 °C
0.68 °C
0.41 °C
0.38 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
1.97 °C
1.02 °C
0.60 °C
0.55 °C
C
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.23 °C
0.28 °C
0.44 °C
0.33 °C
0.40 °C
0.60 °C
0.37 °C
0.45 °C
0.66 °C
0.54 °C
0.63 °C
0.91 °C
D
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.22 °C
0.26 °C
0.39 °C
0.32 °C
0.36 °C
0.53 °C
0.34 °C
0.39 °C
0.56 °C
0.44 °C
0.49 °C
0.69 °C
G
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.24 °C
0.22 °C
0.33 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.33 °C
0.46 °C
L
−200 °C to
900 °C
−200 °C
0 °C
800 °C
0.13 °C
0.08 °C
0.09 °C
0.19 °C
0.12 °C
0.12 °C
0.45 °C
0.28 °C
0.23 °C
0.99 °C
0.62 °C
0.48 °C
M
−50 °C to
1410 °C
0 °C
500 °C
1000 °C
0.11 °C
0.10 °C
0.10 °C
0.16 °C
0.15 °C
0.14 °C
0.30 °C
0.25 °C
0.21 °C
0.64 °C
0.51 °C
0.41 °C
U
−200 °C to
600 °C
−200 °C
0 °C
400 °C
0.25 °C
0.10 °C
0.08 °C
0.37 °C
0.15 °C
0.11 °C
0.71 °C
0.30 °C
0.20 °C
1.48 °C
0.63 °C
0.40 °C
W
0 °C to
2315 °C
600 °C
1200 °C
2000 °C
0.24 °C
0.22 °C
0.33 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.32 °C
0.46 °C
0.36 °C
0.33 °C
0.46 °C

Thermocouple Measurement Characteristics

Range Temperature Display Resolution
Slow / Medium
Sample Rate
Fast
Sample Rate
−270 °C to 2315 °C 0.01 °C 0.1 °C

 

DC Voltage

Maximum Input 50 V on any range
Common Mode Rejection 140 dB at 50 Hz or 60 Hz (1 kΩ unbalance in LOW lead) ±50 V peak maximum
Normal Mode Rejection 55 dB for power line frequency ±0.1 %, ±120 % of range peak maximum
A/D Linearity 2 ppm of measurement + 1 ppm of range
Input Bias Current 30 pA at 25 °C

 

DC Voltage Accuracy

Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1, medium or slow sample rate. For channels x01 through x20 or when using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Channel 1 Ch. x01 – x20 Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
±100 mV 0.0037 % + 0.0035 % add 2 μ add 0.0008 % of range 0.0005 % + 0.0005 %
±1 V 0.0025 % + 0.0007 % add 2 μ add 0.0008 % of range 0.0005 % + 0.0001 %
±10 V 0.0024 % + 0.0005 % add 0.0008 % of range 0.0005 % + 0.0001 %
±50 V 0.0038 % + 0.0012 % add 0.0008 % of range 0.0005 % + 0.0001 %

 

DC Voltage Input Characteristics

Resolution Input Impedance
Range Slow / Medium Fast
±100 mV 0.1 μ 1 μ 10 GΩ [1]
±1 V 1 μ 10 μ 10 GΩ [1]
±10 V 10 μ 100 μ 10 GΩ [1]
±50 V 100 μ 1 mV 10 MΩ ±1 %
[1] – Input beyond ±12 V is clamped. The clamp current is up to 3 mA.

 

DC Current

Input Protection 0.15 A resettable PTC

DC Current Accuracy

Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
Range Accuracy Fast Sample Rate T.C./ °C Outside
18 °C to 28 °C
±100 μA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
±1 mA 0.015 % + 0.0011 % add 0.0008 % of range 0.002 % + 0.001 %
±10 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
±100 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %

 

DC Current Input Characteristics

Resolution
Range Slow / Medium Fast Burden Voltage
±100 μA 0.1 nA 1 nA <1 mV
±1 mA 1 nA 10 nA <1 mV
±10 mA 10 nA 100 nA <1 mV
±100 mA 100 nA 1 μA <1 mV

 

Resistance

Max. Lead Resistance (4-wire ohms) 10 Ω per lead for 100 Ω and 1 kΩ ranges. 1 kΩ per lead on all other ranges.

Resistance Accuracy

Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for 4-wire resistance, medium or slow sample rate. For 2-wire resistance add 0.02 Ω internal resistance if using Channel 1, or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. When using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the Temperature Coefficient numbers by the temperature deviation and add to the accuracy specification
Range Accuracy Fast Sample Rate 1T.C./ °C Outside
8 °C to 28 °C
100 Ω 0.004 % + 0.0035 % add 0.001 % of range 0.0001 % + 0.0005 %
1 kΩ 0.003 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
10 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
100 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
1 MΩ 0.006 % + 0.001 % add 0.002 % of reading plus 0.0008 % of range 0.0005 % + 0.0002 %
10 MΩ 0.015 % + 0.001 % add 0.002 % of reading plus 0.0008 % of range 0.001 % + 0.0004 %
100 MΩ 0.8 % + 0.01 % add 0.01 % of range 0.05 % + 0.002 %

 

Resistance Input Characteristics

Range Resolution
Slow / Medium
Fast Source Current
(open-circuit voltage)
100 Ω 0.1 mΩ 1 mΩ 1 mA (4 V)
1 kΩ 1 mΩ 10 mΩ 1 mA (4 V)
10 kΩ 10 mΩ 100 mΩ 100 μA (6 V)
100 kΩ 100 mΩ 1 Ω 100 μA (12 V)
1 MΩ 1 Ω 10 Ω 10 μA (12 V)
10 MΩ 10 Ω 100 Ω 1 μA (12 V)
100 MΩ 100 Ω 1 kΩ 0.1 μA (12 V)

 

Digital I/O

Absolute Voltage Range –4 V to 30 V
Input Minimum Logic High 2.0 V
Input Maximum Logic Low 0.7 V
Output Type open drain active low
Output Logic Low (<1 mA) 0 V to 0.7 V
Maximum Sink Current 50 mA
Output Resistance 47 Ω

 

Totalizer

Absolute Voltage Range –4 V to 30 V
Minimum Logic High 2.0 V
Maximum Logic Low 0.7 V
Minimum Pulse Width 50 μs
Maximum Frequency 10 kHz
Debounce Time 1.7 ms
Maximum Count 1048575 (20 bits)

 

Trigger

Absolute Voltage Range –4 V to 30 V
Minimum Logic High 2.0 V
Maximum Logic Low 0.7 V
Minimum Pulse Width 50 μs
Maximum Latency 100 ms

 

Alarm Output

Absolute Voltage Range –4 V to 30 V
Output Type open drain active low
Output Logic Low (<1 mA) 0 V to 0.7 V
Maximum Sink Current 50 mA
Output Resistance 47 Ω

 

1586-2588 DAQ-STAQ Input Module Specifications

Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch <50 mΩ
Basic CJC Accuracy 0.25 °C

 

1586-2586 High-Capacity Input Module Specifications

Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch <50 mΩ
Basic CJC Accuracy 0.6 °C

 

Jual FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER Dengan Harga murah dan cari produk terbaik lainnya dari kategori  dari Thermometer Merek FLUKE  Gratis biaya pengiriman untuk wilayah Jakarta dan dapat dikirim ke seluruh Indonesia. Dapatkan hanya di toko online Kucari.com, belanja online alat ukur dan alat survey mudah dan aman.

Kucari.com menyediakan berbagai alat ukur dan instruments dari supplier dan distributor resmi yang tersebar dibeberapa kota di Indonesia seperti Jakarta, Bandung, Bekasi, Depok, Cikarang, Tangerang, Lampung, Pontianak, Jogja, Semarang, Solo, Batam, Padang, Pekanbaru, Malang, Surabaya, Medan, Makassar, Balikpapan, Samarinda, Pelembang, Riau, Aceh, Manado, dan Bali.

Daftarkan perusahaan Anda!

Anda adalah Agen, Vendor, Supplier & Distributor peralatan ukur dan perkakas untuk wilayah Indonesia? Daftarkan perusahaan Anda disini

Kucari.com merupakan situs penyedia direktori peralatan dan perkakas bisnis sebagai media promosi online berbasis web yang dapat menghubungkan supplier, distributor, agen, vendor dan pembeli antar bisnis (B2B – Business to Business) dan kalangan B2C (Business-to-Customer) dalam 24 Jam nonstop menjangkau seluruh wilayah Indonesia .

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “FLUKE 1586A SUPER-DAQ PRECISION TEMPERATURE SCANNER”

There are no reviews yet.